The method describes how to determine the temperature of water using a thermometer.
Water intended for use as an ingredient in the production of beer (brewing liquor) or other foods
Measurement of the water temperature at the sampling location as well as the ambient room temperature is of consequence for evaluating analysis results, the solubility of gases in water and possible reactions. Sudden variations in the temperature of well water might indicate that surface water is entering the well.
The method describes the conditions required for carrying out sensory analysis.
beer, beer-based beverages, non-alcoholic beverages, mineral water
One of the basic prerequisites for properly conducting sensory analysis is ensuring that it occurs under the correct tasting conditions and that the samples are at a suitable temperature.
The gelatinization temperature can be determined using a rotary viscometer (e.g., Amylograph or Viscograph, Brabender GmbH & Co. KG, Germany [4] or a Rapid-Visco-Analyser, RVA, Perten Instruments, a PerkinElmer Company, USA [8]).
A suspension consisting of a finely ground sample and water is produced, whose precise mixing ratio should correspond to the analysis protocol for the adjunct in question. However, since for many cereals and pseudocereals no official analysis protocol exists, the initial weight for the adjuncts listed in table 2 has been determined empirically [3].
Once the suspension is prepared it is attempered according to a pre-programmed temperature/time program, and the viscosity is determined on a continuous basis by means of a rotor and a rotary torque measurement (fig. 1). When gelatinization begins, an increase in the viscosity is registered, and the corresponding sample temperature is defined as the gelatinization temperature. The standard evaluation criterion (PT) is a viscosity increase of at least 24 cP (≙ mPas) within six seconds.
Whole hops intended for use in beer brewing or elsewhere in the food industry
Evaluation of the appearance of hop cones is performed through visual and manual inspection.
Malt intended for use in beer brewing or elsewhere in the food industry
Viscometric Determination of Gelatinization Temperature (GT)
The gelatinization temperature (GT) can be determined using a rotary viscometer (e.g., amylograph or viscograph, Brabender GmbH & Co. KG, Germany [7] or Rapid-Visco-Analyser (RVA), Perten Instruments, a PerkinElmer Company, USA [8]).
Unlike the analysis method for adjuncts which do not contain a large amount of enzymes, for the analysis of barley malt, a mash with a mash to sparge ratio of 1 : 4 (similar to that commonly found in the brewing process) is used [9]. The sample is heated according to a programmable temperature/time program (refer to table 1) and the viscosity is measured using measuring stirrer throughout the process.
A gelatinization begins to occur, an increase in viscosity is registered; temperature of the sample is measured and identified as the corresponding gelatinization temperature. An increase in viscosity of a minimum of 24 cP (mPa × s) within six seconds is the evaluation criterion for the pasting temperature.
Determination of the concentration of dissolved carbon dioxide in carbonated beverages in bottles and cans
The total gas pressure in beer is measured after the beer has been forcefully shaken. The carbon dioxide is then bound through the addition of potassium hydroxide. The amount of air in the beer contributes the remaining volume of gas. Once the value for the total pressure has been corrected by subtracting the quantity of air present in the beer, the carbon dioxide can be measured [1].