B-420.10.100 [2020-10] Foam Stability, Lg-Foamtester

Application/Purpose

Determination of the foam stability

Scope of Application

Beer and beer-based beverages

Principle

In an Lg foam tester, the foam stability is determined by measuring the time it takes for the foam to collapse in a glass cylinder.

The foam is produced by pressing a constant beer volume through a nozzle (Ø 0.6 mm). The precise metering of a predetermined quantity of beer is achieved by time-controlled operation of the valve in conjunction with pressurizing the sample bottle to 2.5 bar (± 5 mbar). As the foam collapses, the height is measured optically in the glass cylinder [1]. 

 